SWMM5 Bubble Plot of Continuity Error

The overall continuity error at any time during the simulation is simply the total inflow minus the total outflow. The total inflow is the dry weather, wet weather, groundwater, I&I inflow, external inflow and the initial network storage. The total outflow is the amount of surface flooding, outfall flow, reacted flow and the final storage.

The continuity error = Total Inflow - Total Outflow

The continuity error can be variable over time as this graph of the total inflow, total outflow and continuity error over time shows for the classic extran example from SWMM 3 and SWMM 4. The continuity error can be negative or positive at each saved time step and it tends to balance out over time. As you can imagine depending on how long the simulation lasts the continuity error may be much greater than zero. If you can the simulation to dry weather flow is reached in the sanitary network or the stormwater network has drained the continuity error will be better.



If we look at a bubble chart of the continuity error over time (with the bubble size the continuity error) and the y axis the Total Inflow to the network you can see how continuity error increases and then decreases over time. The white bubbles are negative continuity error points.